Interdendritic pores in the FCD 600 test bar which failed the tensile test. Dark oxided area is micro-voids that was interconnected to the open air.
Sharp points of the shrinkage pore served as stress raisers, and thus, crack initiation sites.
Sharp points of the angular carbides and pores are tickets to the hell because they are potential origins for fatigue cracks.